Online UPS 1kVA/2kVA/3kVA Double Conversion with Competitive Price
Features:
1. Sine-wave output:
True sine-wave output with less than 3% THD.
2. Double Conversion Design:
Zero transfer/ complete isolation of input AC.
3. UPS Monitoring Software:
Powerful true RS232 communication via the enclosed software
To manage and safely shutdown operating systems.
4. Network RJ45/11 protection:
Complete powerful network and phone line surge protection.
5. AC Surge Suppressor:
Powerful multi-stage surge components that exceed IEEE requirements.
6. SNMP Slot Option:
Allows for remote monitoring and control via.
7. Sleep Mode:
Worry free battery management. The unit turns itself off after ten seconds to conserve battery
Power when no power needs are detected.
8. Battery level indicators:
LED”s indicate battery levels.
9. Load Sensing:
The incorporated LED load indicators allow IT professionals to manage backup time and balance power loads.
10. Low Battery indicators:
The low battery level indicator will warn of eminent UPS shutdown two full minutes before unit shuts down.
11. Replace Battery indicators:
A preventative measure that indicates when batteries must be replaced to prevent server crashes.body {background: #C0EBC6 !important;}div {background-color: #C0EBC6 !important;}header,nav,table,th,tr,td,dl,ul,li,ol,fieldset,form,h1,h2,h3,h4,h5,h6,pre {background: transparent !important;}* {color: #363636 !important;}a:link,a:link *,a:link:hover,a:link:hover *,a:link:active,a:link:active * {color: #3E3822 !important;}a:visited,a:visited *,a:visited:hover,a:visited:hover *,a:visited:active,a:visited:active * {color: #0060BF !important;}body {background: #C0EBC6 !important;}div {background-color: #C0EBC6 !important;}header,nav,table,th,tr,td,dl,ul,li,ol,fieldset,form,h1,h2,h3,h4,h5,h6,pre {background: transparent !important;}* {color: #363636 !important;}a:link,a:link *,a:link:hover,a:link:hover *,a:link:active,a:link:active * {color: #3E3822 !important;}a:visited,a:visited *,a:visited:hover,a:visited:hover *,a:visited:active,a:visited:active * {color: #0060BF !important;}
body {background: #C0EBC6 !important;}div {background-color: #C0EBC6 !important;}header,nav,table,th,tr,td,dl,ul,li,ol,fieldset,form,h1,h2,h3,h4,h5,h6,pre {background: transparent !important;}* {color: #363636 !important;}a:link,a:link *,a:link:hover,a:link:hover *,a:link:active,a:link:active * {color: #3E3822 !important;}a:visited,a:visited *,a:visited:hover,a:visited:hover *,a:visited:active,a:visited:active * {color: #0060BF !important;}body {background: #C0EBC6 !important;}div {background-color: #C0EBC6 !important;}header,nav,table,th,tr,td,dl,ul,li,ol,fieldset,form,h1,h2,h3,h4,h5,h6,pre {background: transparent !important;}* {color: #363636 !important;}a:link,a:link *,a:link:hover,a:link:hover *,a:link:active,a:link:active * {color: #3E3822 !important;}a:visited,a:visited *,a:visited:hover,a:visited:hover *,a:visited:active,a:visited:active * {color: #0060BF !important;}body {background: #C0EBC6 !important;}div {background-color: #C0EBC6 !important;}header,nav,table,th,tr,td,dl,ul,li,ol,fieldset,form,h1,h2,h3,h4,h5,h6,pre {background: transparent !important;}* {color: #363636 !important;}a:link,a:link *,a:link:hover,a:link:hover *,a:link:active,a:link:active * {color: #3E3822 !important;}a:visited,a:visited *,a:visited:hover,a:visited:hover *,a:visited:active,a:visited:active * {color: #0060BF !important;}
Model |
C1KS |
C2KS |
C3KS |
|
Rated Power |
VA/W |
1kVA / 0.7kW |
2kVA / 1.4kW |
3kVA / 2.1kW |
Input |
Nominal Voltage |
220VAC |
||
Voltage Range |
115 ~ 300VAC |
|||
Frequency Range |
46 ~ 54Hz(default), user adjustable within 40~60Hz |
|||
Power Factor |
0.97 |
|||
Connection |
IEC320 -10A inlet |
IEC320 -16A inlet |
||
Output |
Voltage |
220VAC ± 2% |
||
Frequency |
46~54Hz or 50Hz ± 0.2Hz (Line mode) |
|||
Waveform |
Pure Sine Wave |
|||
Distortion |
3% |
4% |
||
Overload Capability |
108% ~ 150% for 30 sec., ³150% for 300 ms |
|||
Current Crest Ratio |
3:1 |
|||
Connections |
IEC320 -10A *4 |
IEC320 -10A *6 |
IEC320 -10A *3 and |
|
Battery |
Type |
Sealed, Maintenance free, Lead-Acid |
||
Nominal DC Voltage |
36VDC |
96VDC |
||
Back-up Time |
Depends on the capacity of the external battery bank |
|||
Connection |
External Battery Socket |
|||
Bypass |
Automatic Transfer |
On overload and UPS failure |
||
Before UPS Power-on |
Default “NO”, user adjustable to “YES” |
|||
Voltage Range |
80 ~ 264VAC (Default), user adjustable within 80 ~ 286VAC |
|||
Transfer Time |
0 ms; less than 4 ms from inverter to bypass and vice versa |
|||
LED Indicators |
Status |
Load level / Battery level, Battery , Utility Power, Inverter, Bypass, Overload, Fault |
||
Audible Alarm |
Bypass, On battery mode, Battery low, Overload, Fault |
|||
Acoustic Noise |
At 1 meter distance |
45 dBA |
50 dBA |
|
Communications |
DB-9 Port |
RS-232 Serial Interface |
||
Intelligent Slot |
Options: WebPower, AS400 Card or WinPower CMC |
|||
Network Surge Protection |
RJ45 I/O port available for 10 base-T network or Fax/Modem |
|||
Environmental |
Operating Temperature |
0 ~ 40°C |
||
Operating Humidity |
20 ~ 90% non-condensing |
|||
Weight |
Net (Kg) |
7 |
13.5 |
14 |
Dimensions |
W x D x H (mm) |
145 x 400 x 220 |
192 x 460 x 348 |