Online UPS Power Regulation Backup 6K-20kVA with Pfc Over 0.99
Product Description
No Break Online UPS Power 6k-20kVA High Frequency Tower UPS with 0.99 Power Factor
Our Uninterruptible power system (UPS) advantages
1.Excellent line network adaptability Wide input voltage range:110-330V Wide input frequency range:40~70Hz
2.Advanced performance specifications
Output power factor 1.0 optional,High energy efficiency above 94%,Input THDI is lower than 5%
Output THDV is less than4% nonlinear load
3.Intelligent monitoring and management methods
4.Strong load and overload capacity
Specifications:
| Model | 1K | 2K | 3K | 6K | 10K |
| Phase | Single phase with ground | ||||
| Input | |||||
| Rate capacity | 1KVA/900W | 2KVA/1.8KW | 3KVA/2.7KW | 6KVA/6KW | 10KVA/10KW |
| Rate voltage | 110/115/120/127VAC or 220/230/240VAC | 220/230/240VAC | |||
| Turn on voltage range | 55-150VAC or 110-300VAC ≤50% load | 110-300VAC ≤50% load | |||
| 80-150VAC or 160-300VAC ≤100% load | 176-300VAC ≤100% load | ||||
| Frequency range | 40~70Hz | 46~54Hz or 56~64Hz | |||
| Power factor | ≥0.99 100% load | ||||
| THDI | ≤5% | ≤4% | |||
| Output | |||||
| Rate voltage | 110/115/120/127VAC or 220/230/240VAC | 220/230/240VAC | |||
| Voltage regulation | ±1% | ||||
| Line mode frequency | 47~53Hz or 57~63Hz | 46~54Hz or 56~64Hz | |||
| Bat mode frequency | 50Hz or 60Hz ±0.1Hz | ||||
| Voltage harmonic | ≤2% R load | ≤1% R load | |||
| ≤4% RCD load | ≤4% RCD load | ||||
| Crest ration | 3:01 | ||||
| Line-Bat transfer | 0ms | ||||
| INV-Bypass transfer | ≤4ms | 0ms | |||
| Over load | 100%±5%<load≤110%±5%:10min;110%±5%< load ≤130%±5%:1min;load>130%±5%:1s; ( transfer to bypass and alarm) Note: 6-10K line mode | ||||
| Efficiency | |||||
| Line mode | > 90% | > 91% | > 91% | > 94% | > 94% |
| Bat mode | > 89% | > 89% | > 90% | > 91% | > 91% |
| Battery | |||||
| Number | 3 | 6 | 8 | 16 or 20(20 only long) | |
| Charger voltage | 41.0VDC | 82.1VDC | 109.6VDC | 218.4VDC/273VDC | |
| Charge current (stand) | 1.5A | 1.2A | 1A | ||
| Charge current(long) | 1A/2A/4A/6A/8A(adjustable) | 4.0A | |||
| Size(length*width*height)and weight | |||||
| Stand UPS(mm) | 397*145*220 | 421*190*318 | 421*190*318 | 369*190*688/ | 442*190*688 |
| Weight(kg) | 12 | 22.5 | 32.2 | 54 | 66 |
| Long time UPS(mm) | 397*145*220 | 421*190*318 | 369*190*318 | 442*190*318 | |
| Weight(kg) | 6.3 | 10.5 | 11.7 | 13 | 16 |
| Environment | |||||
| Work temperature | 0ºC~40ºC | ||||
| Work humidity | 20%~95% | ||||
| Audible noise | ≤50dB | ≤55dB | ≤58dB | ||
| Communication | RS-232/USB/SNMP card adjustable | ||||