Create maximum value for customers.

WZ-FC/B intelligent fire pump inspection cabinet

Short Description:

With the rapid development of the city, various buildings are increasing day by day, various flammable materials are widely used, and people’s awareness of fire prevention is not strong. This greatly increases the possibility of fire. “Although every building is currently equipped with Fire extinguishing system, but experience and lessons have proved that the success of fire remediation mainly depends on whether the fire water supply equipment is in good condition. The fire pump is a vertical part of the fire extinguishing system. To be 100% effective, due to the long-term idle state and the humid environment of the pump room, it is easy to cause the fire pump shaft and impeller to corrode, rust and the electrical components cannot be used normally, and even in the event of a fire, the fire pump cannot work normally. It is impossible to put out the fire and endanger the safety of people’s lives and property.


Product Detail

Product Tags

Product overview
With the rapid development of the city, various buildings are increasing day by day, various flammable materials are widely used, and people's awareness of fire prevention is not strong. This greatly increases the possibility of fire. "Although every building is currently equipped with Fire extinguishing system, but experience and lessons have proved that the success of fire remediation mainly depends on whether the fire water supply equipment is in good condition. The fire pump is a vertical part of the fire extinguishing system. To be 100% effective, due to the long-term idle state and the humid environment of the pump room, it is easy to cause the fire pump shaft and impeller to corrode, rust and the electrical components cannot be used normally, and even in the event of a fire, the fire pump cannot work normally. It is impossible to put out the fire and endanger the safety of people's lives and property.

In order to solve these fire protection problems, our company has independently developed the WZ-FC intelligent fire inspection system integrating alarm, monitoring, control and management in combination with the above problems, and has been put into production and use in batches; this product can prevent fire protection. The function of the water pump is rusted, damp, abnormal water pump and other faults, so as to achieve the purpose of "keeping soldiers for one day and using them for a while", this equipment also has the automatic exchange of main and backup water pumps. When the main pump fails, the backup pump is automatically put into use. The main and backup power Automatic mutual switching, when the main power supply fails, the backup power supply will automatically switch on and other functions, and provide data remote transmission, image monitoring, fault alarm, information printing and other functions for all the above functions; this product complies with the industry mandatory standards promulgated by the Ministry of Public Security. "GA30.2 Performance Requirements and Experience Methods for Fixed Fire-fighting Water Supply Equipment" and the national standard GB16806, and passed the national CCCF compulsory certification.

Model and meaning

Model: WZ -FC/B-□□/□

WZ

Wanzheng Power Co., Ltd.

FC

Fire inspection cabinet

B

B means deluxe type, G means standard type

□□

High power of fire inspection pump (single kW)

The number of circuits of the fire inspection pump

Use environment
■ Ambient temperature: -10~+40℃
■ Ambient humidity: 0~90% without condensation
■ Altitude: less than 1000 meters

Product Features
■ The frequency converter is used to inspect the water pump, the starting current is small, the speed of the water pump is low, and the mechanical impact on the water pump is small; thus prolonging the service life of the fire water pump; especially for high-power water pumps, it is more meaningful.
Bright
■ The drive power of frequency conversion inspection is small, and the operation is efficient and energy-saving. Its power is about 1.35% of the power of power frequency inspection, which greatly saves power resources.
■The fire inspection cabinet can automatically inspect according to the set period, without manual operation, and is equipped with a variety of communication interfaces, which can realize remote fire monitoring, and know the situation of the fire pump unit at any time, which is convenient for management.
■ Adopt Chinese large LCD touch screen as man-machine interface, easy to operate, simple and intuitive.
■ CPU adopts Siemens PLC, with stable performance, safety and reliability.
■ With fault alarm, power failure flash memory function, fault storage record function, can store 256 fault records, which is convenient for maintenance personnel to repair and analyze faults.
■ In the process of patrol inspection, if there is a fire signal, immediately exit the patrol inspection, and immediately start the fire hydrant pump and spray pump.
■ The fire inspection device has a complete interface function, which can be networked with the company's monitoring center or the computer of the public security fire department, 24-hour real-time monitoring and monitoring of the equipment, realizing computer remote monitoring and all-round network center management, thus further strengthening safety monitoring .
■ The wiring of the fire inspection device is convenient, and it can be used together with the control cabinet produced by any switch factory.

Scope of use
The system is suitable for living quarters, production bases, office buildings, shopping malls, hotels, guesthouses, schools, warehouses, hospitals, troops, etc. It is also suitable for the renovation of old fire protection engineering projects, and the original fire protection basic equipment can be reasonably used to provide Users save costs.

Function table

Inspection cabinet function Way Inspection cabinet function Way
Periodic automatic inspection can be set according to the setting Bring your own The main circuit switching element can be inspected for no more than 2s custom made
Low-speed, low-frequency, no-pressure mode inspection one by one Bring your own Pipe network protection function, with pressure inspection function custom made
In case of fire signal, exit inspection and immediately put into operation Bring your own SMS alert function custom made
With sound and light alarm function Bring your own With 485 communication function, the fire system can be networked custom made
Fault storage record function Bring your own Pool liquid level and pipeline water pressure alarm function custom made
There are overvoltage, overcurrent, short circuit, lack of phase protection functions Bring your own Water test unit function custom made

Attachment: "GA30.2 Performance requirements and test methods for fixed fire-fighting water supply equipment" Article 5, point 4, the inspection function stipulates:
The equipment that the fire pump is in non-operational state for a long time shall have the inspection function and shall meet the following requirements:
1. The equipment should have automatic and manual inspection functions, and the automatic inspection cycle should be set as needed
2. The fire pumps are operated one by one according to the fire fighting mode, and the running time of each pump is not less than 2min
3. The equipment should be able to ensure that during the inspection process, it will automatically exit the inspection and enter the fire operation state when encountering a fire signal.
4. There should be sound and light alarms when faults are found during inspection. For equipment with fault memory function, it should record the type of fault and the time when the fault occurred, etc. There should be a lot of fault information, and the display should be clear and easy to understand.
5. The equipment that adopts the power frequency inspection method should have measures to prevent overpressure, and the equipment that is set up to inspect the pressure relief circuit, the circuit setting should be safe and reliable.
6. For equipment that uses electric valves to adjust the water supply pressure, the electric valves used should participate in the inspection.

Part V of "GB27898-2011: Fixed Fire-fighting Water Supply Equipment" stipulates:
1. The equipment should have manual inspection and inspection prompt functions, and the inspection prompt period should be set as needed, but the longest period cannot exceed 360h.
2. The operation method of inspection should be simple and specified in the "Operation Instructions".
3. During the inspection, the fire pumps should be started one by one, and the running time of each pump should not be less than 2min under the rated working conditions.
4. There should be an audible and visual alarm when a fault occurs during the inspection.


  • Previous:
  • Next:

  • Related Products